Simplifying delta covariance in ProcessorOdom2/3D
In computeCurrentDelta, the immediate delta covariance was not taking into account the covariance provided by the capture but instead the distance (linear and orientation) represented by the delta. We agreed with Joan that this was a bit confusion and too restraining for some application. A lot of tests and demos are implemented this way and have to be changed (in core mostly).